PerkinElmer

深圳彩票网:进样系统

OF

二元彩票网 www.mwbxj.com 准确,可重复的结果源于完美的进样系统,这就是为什么我们投入大量资源用于测试和校验我们的进样系统配件 - 以确保您在仪器的整个生命周期,每次都能获得最好的结果。 我们提供多种进样系统,包括:

  • 紫外进样系统
  • 红外进样系统
  • 顶空进样系统
  • 其他

  • 产品与服务

  • 资源,活动及更多信息

缩小结果
产品类型
  • Accessories (108)
  • Consumables (12)
  • Service Parts (6)
材料
  • Ge (10)
  • ZnSe (9)
  • AMTIR (6)
  • Diamond/ZnSe (1 Reflection) (6)
  • Diamond/ZnSe (9 Reflection) (5)
  • Diamond/ZnSe (3 Reflection) (4)
  • Ge (1 Reflection) (3)
  • KRS-5 (1 Reflection) (3)
  • KRS-5 (2)
  • Coated ZnSe (2)
型号兼容
  • Frontier (38)
  • Spectrum One (27)
  • Spectrum 400 (26)
  • Spectrum 100 (26)
  • Spectrum 65 (25)
  • Spectrum Two (12)
  • LAMBDA 750 (6)
  • LAMBDA 950 (6)
  • LAMBDA 650 (6)
  • LAMBDA 850 (6)
  • LAMBDA 1050 (6)
  • NIRM (3)
  • NIRA II (3)
  • Spectrum One/100/400/65/Frontier (1)
  • Spectrum BX/RX (1)
  • Spectrum GX (1)
产品品牌名称
  • Clarus (1)
  • Spectrum Two N (1)
产品组
  • Top Plates (24)
  • Thermostatting Accessory (11)
  • HATR Accessory (9)
  • Desolvation Accessory (6)
  • Miracle Accessory (5)
  • Optical Bench (5)
  • Polarizer (4)
  • UATR Accessory (4)
  • NIR Accessory (3)
  • Sampling System (3)
  • Top Plate Accessory (3)
  • Depolarizers (2)
  • UATR Polarization Accessory (2)
  • Diffuse Reflectance Accessory (2)
  • Total Emission Accessory (1)
  • ATR Pressure Arm (1)
  • Light Shield (1)
  • Sample Holder (1)
  • Heatable Transmission Accessory (1)
  • Clamp Assemblies and Replacement Parts (1)
  • Imaging Accessory (1)
  • Pressure Gauge (1)
  • GladiATR Diamond (1)
  • Fiber Optic Accessory (1)
  • Polarization Accessory (1)
  • Variable Angle Accessory (1)
  • Fixed Angle Accessory (1)
  • Silver Gate (1)
  • Powder Press (1)
  • Volatiles Cover (1)
  • IR Specular Reflectance Set (1)
  • NIRM Accessory (1)
  • Variable-Angle Accessory (1)
技术类型
  • ATR (53)
  • Diffuse Reflectance (9)
  • Specular Reflectance (3)
  • FT-IR (1)
  • Fluorescence Sampling (1)
  • Fiber Optics (1)

"进样系统" 1-50126 产品与服务

每页
PerkinElmer

Fiber Coupling Module-Req./ Inc.* for LAMBDA 465

Used for measuring liquid samples; intended for hazardous samples. Includes N4101048, a transmission dip probe and a 10 mm pathlength tip. Easy to clean.
PerkinElmer

Diffuse Reflectance Accessory for LAMBDA 465

Used for measuring the diffuse reflectance (SCE) and color analysis for solid and powder samples. It has a spectral range of 270~1000 nm (UV and Visible), and a port size of 10.00 and 5.00 mm (selectable). Included is a Xenon Lamp (150W), and a White Standard (1 each).
Spectrum Two N with NIRM accessory and optional Sample Vial Holder

Sample Vial Holder

The Sample Vial Holder for use with the Near-Infrared Reflectance Module (NIRM) and Near Infrared Reflectance Accessory (NIRA II) securely holds and aligns vials on the accessory window.
8-Position Multicell Holder for LAMBDA 365

8-Position Multicell Holder for LAMBDA 365

Accommodates any standard 10 mm cells; up to 8 samples.
Peltier Temperature Controller (without Cell) for LAMBDA 265

Peltier Temperature Controller (without Cell) for LAMBDA 465

Comes with internal liquid cooling system and N2 purge gas capability, magnetic stirrer control, and emergency power off switch.
Near Infrared Reflectance Module (NIRM) for Spectrum Two N FT-NIR

Near Infrared Reflectance Module (NIRM) for Spectrum Two N FT-NIR

The Near Infrared Reflectance Module for the Spectrum Two N FT-NIR provides a convenient and sensitive method for analyzing opaque or highly scattering solid samples such as pharmaceuticals, food products, soap powders, coal, clay, soil, paper, painted surfaces, polymer foam, and catalysts.
Fiber Coupling Module-Req./Not Inc.* for LAMBDA 365

Fiber Coupling Module-Req./Not Inc.* for LAMBDA 365

Fiber Optic Probe Module Only for L365. When combined with Fiber Optic Probe it can be used for measuring liquid samples; intended for hazardous samples.
Spectrum Two N with NIRM accessory and optional Sample Spinner

100 mm Sample Spinner

The Sample Spinner for use with the Near-Infrared Reflectance Module (NIRM) and Near-Infrared Reflectance Accessory (NIRA II) provides representative sampling of non-homogenous samples.
Spectrum Two N HTM

Heatable Transmission Module (HTM) for Spectrum Two Platform

The Heatable Transmission Module (HTM) for the Spectrum Two? platform (including both the Spectrum Two FT-IR and Spectrum Two N? FT-NIR) allows for easy elevated temperature measurements on samples in the Mid-IR or Near-IR regions of the spectrum, the module accepting fixed pathlength sealed.
Spectrum Two N with NIRM accessory and optional Sample Spinner

60 mm Sample Spinner

The Sample Spinner for use with the Near-Infrared Reflectance Module (NIRM) and Near-Infrared Reflectance Accessory (NIRA II) provides representative sampling of non-homogenous samples.
Water Jacketed Automatic Referencing Stage for LAMBDA 465

Water Jacketed Automatic Referencing Stage for LAMBDA 465

Accommodates any standard 10 mm cells 2-Position for reference and sample. Unique accessory provides long term stability for monitoring kinetics reactions. Use recirculating liquid to control the temperature of a sample and reference solution for simultaneous analysis.

UATR Polarization Accessory for Spectrum One (1 Reflection)

The UATR Polarization Accessory is designed to provide reproducible, high quality ATR spectra of materials that polarize light through the use of a variable-angle polarizer mount.

Apex HF-FAST for NexION

Apex HF-FAST system with integrated CTFE Fluoropolymer high-flow valve for PE NexION ICPMS. Includes one PFA-100 nebulizer, one PFA-ST nebulizer and adapter to NexION. (NOTE: Requires SC-Autosampler with FAST enabled)
PerkinElmer

Magnetic Attenuator, 10%

Used to provide additional attenuation when measuring high absorbance materials.

UATR Accessory for Frontier

The Universal ATR is an excellent general accessory for the analysis of solids and liquids, producing high quality spectra through the use of a pressure arm, allowing for good contact of the sample with the diamond/ZnSe crystal.

Top Plates for UATR Accessory

We offer replacement top plates for use with the PerkinElmer Universal ATR accessory.

UATR Polarization Accessory for Frontier

The UATR Polarization Accessory is designed to provide reproducible, high quality ATR spectra of materials that polarize light through the use of a variable-angle polarizer mount.
PerkinElmer

ATR MIRacle for Spectrum One/100/400/65/Frontier

A single reflection ATR accessory designed for the analysis of highly absorbing solid, semi-liquid and liquid samples. Easily changeable crystal plate design enables analysis of a broad spectrum of sample types while ensuring constant sampling pathlength.

PerkinElmer

Value HATR Trough Top Plate, KRS-5

This Trough Top Plate features a KRS-5 (Thallium Bromoiodide) crystal, for use with the PerkinElmer Value HATR accessories.

Premium HATR Trough Top Plate, 60° Ge

This Trough Top Plate features a 60° Germanium (Ge) crystal, for use with the PerkinElmer Premium HATR accessories.
PerkinElmer

Polarizer Crystal for PerkinElmer Lambda 800/900 Double Polarizer Drive

High-performance polarizer. One set to update the double polarizer drive. For equal energy level in sample and reference beam, two sets are necessary, P/N B0505530 and P/N B0501282. Wavelengthrange: 300 to 900nm (PerkinElmer Lambda 800) and 300 to 2600nm(PerkinElmer Lambda 900).

Apex Q system for NexION

Apex Q system for the NexION 300/350. Includes one PFA-100 and PFA-ST nebulizer and adapter to NexION.

UATR Accessory for Spectrum One

The Universal ATR is an excellent general accessory for the analysis of solids and liquids, producing high quality spectra through the use of a pressure arm, allowing for good contact of the sample with the diamond/ZnSe crystal.
PerkinElmer

High Performance Sample Area Fiber Interface

With SMA connectors, PerkinElmer solids probe connector and integral detector. Includes software scan procedures and radio controlled mouse. Can be used with compatible 3rd party fiber probes.
PerkinElmer

Peltier Thermostatted Reference Holder for Routine Peltier System

Peltier temperature controlled single cell holder for the reference position. Also included in this product are the power supply, power cables, and User's Guide.
Requires the LAMBDA 25, 35, 45 Accessory Board (L6000500).
PerkinElmer

ATR MIRacle for Spectrum BX/RX

A single reflection ATR accessory designed for the analysis of highly absorbing solid, semi-liquid and liquid samples. Easily changeable crystal plate design enables analysis of a broad spectrum of sample types while ensuring constant sampling pathlength.

Premium HATR Accessory for Spectrum One, ZnSe Flat Top Plate

This Premium HATR Accessory for the Spectrum One allows for superior performance and simple samping of solids, polymer films, and powders.

Premium HATR Trough Top Plate, 30° Ge

This Trough Top Plate features a 30° Germanium (Ge) crystal, for use with the PerkinElmer Premium HATR accessories.

Premium HATR Trough Top Plate, 45° Ge

This Trough Top Plate features a 45° Germanium (Ge) crystal, for use with the PerkinElmer Premium HATR accessories.

Premium HATR Accessory for Spectrum One, ZnSe Trough Top Plate

This Premium HATR Accessory for the Spectrum One allows for superior performance and simple samping of liquids, powders, pastes, and gels.
PerkinElmer

Magnetic Attenuator, 1%

Used to provide additional attenuation when measuring high absorbance materials.
PerkinElmer

ATR MIRacle for Spectrum GX

A single reflection ATR accessory designed for the analysis of highly absorbing solid, semi-liquid and liquid samples. Easily changeable crystal plate design enables analysis of a broad spectrum of sample types while ensuring constant sampling pathlength.

PerkinElmer

Value HATR Accessory for Spectrum Two, ZnSe Flat Top Plate

This Value HATR Accessory for the Spectrum Two allows for excellent performance and simple samping of solids, polymer films, and powders.
PerkinElmer

9+1 Peltier System

Includes the Peltier 9-Sample Position Accessory for the sample position and the Single Reference Accessory for the reference position.
PerkinElmer

Powder Press for Premium HATR Accessory

This Powder Press is for use with the PerkinElmer Premium HATR Accessory to allow for the compacting of soft powder samples to prepare for analysis by HATR.

Premium HATR Flat Top Plate, 60° ZnSe

This Flat Top Plate features a 60° Zinc Selenide (ZnSe) crystal, for use with the PerkinElmer Premium HATR accessories.
Variable-Angle Specular Reflectance Accessory for the Frontier

Variable-Angle Specular Reflectance Accessory for the Frontier

The Variable-Angle Reflectance Accessory allows measurement of reflectance specta at angles of incidence between 15o and 80o. Includes Flat Reference Mirror and three Aperture masks (2 mm, 5 mm, and 10 mm).
PerkinElmer

Premium HATR Accessory for Spectrum One, ZnSe Trough Top Plate

This Premium HATR Accessory for the Spectrum One allows for superior performance and simple samping of liquids, powders, pastes, and gels.
PerkinElmer

Near Infrared Reflectance Accessory (NIRA) for Frontier

The Near Infrared Reflectance Accessory (NIRA) is designed for diffuse reflectance measurements of light-scattering solids, liquids, and powders using the Frontier FT-NIR or FT-IR/NIR spectrometer.

"进样系统" 1-50126 产品与服务

每页
727| 14| 597| 140| 854| 857| 511| 364| 290| 845|